Using expired drotaverine for corrosion protection of steel in HCl solution

Авторлар

  • Liudmila Tsygankova Derzhavin Tambov State University, Tambov, Russia
  • Victoriya Bryaksina Derzhavin Tambov State University, Tambov, Russia
  • Aleksandr Uryadnikov Derzhavin Tambov State University, Tambov, Russia
  • Ljubov Kanaeva Derzhavin Tambov State University, Tambov, Russia

DOI:

10.15328/cb1403

Кілт сөздер:

corrosion, steel, inhibition, hydrochloric acid, drotaverine, polarization, gravimetry, impedance

Аңдатпа

In the last two decades, the scientific literature has widely covered the use of expired medicinal preparations for anticorrosion protection of metals. The aim of this work is to study expired Drotaverine (No-shpa) as a corrosion inhibitor for St3 carbon steel in a 1 M HCl solution. Drotaverine concentrations ranged from 20-80 mg/L.
Studies were conducted using gravimetry, potentiodynamic polarization, impedance spectroscopy, and scanning electron microscopy. Gravimetric studies of Drotaverine’s inhibitory effect were carried out at room temperature for 2 and 24 hours, and at 80°C for 0.5 hours, showing a protective effect (Z, %) of 72, 82, and 96%, respectively, at a concentration of 80 mg/L. The Z values calculated from polarization and impedance measurements were close to those determined gravimetrically. The surface coverage of the electrode by the inhibitor was estimated, and it was shown that Drotaverine adsorption conforms to the Langmuir isotherm. The calculated free energy of adsorption, equal to -29 kJ/mol, indicates physical adsorption of the drug on the steel surface with some contribution from chemisorption. Drotaverine causes a deceleration of both cathodic and anodic electrode reactions.

 

Әдебиеттер тізімі

1 Suraj B, Shitole N, Lonkar SJ (2014) Chem Pharm Res 6:1865-1872.

2 Pathak RK, Mishra P (2016) Intern J Sci Res 5(4):671-677.

3 Verma С, Chauhan DS, Quraishi MA (2017) J Mater Environ Sci 8(11):4040-4051.

4 Berisha A (2022) Electrochem 3(1):28-41. https://doi.org/10.3390/electrochem3010002

5 Anaee RA, Hameed IR, Hameed MA, Naser SA, Mohammed MK (2019) J Mol Liq 279:594-602. https://doi.org/10.1016/j.molliq.2019.01.169

6 Salah E (2021) Int J Electrochem Sci 16:150-172. https://doi.org/10.20964/2021.01.27

7 Golestani G, Shahidi M, Ghazanfari D (2014) Appl Surf Sci 308:347-362. http://doi.org/10.1016/j.apsusc.2014.04.172

8 Fouda AS, Shalabi K, E-Hossiany A (2016) J Bio Tribo Corros 2:18-26. http://doi.org/10.1007/s40735-016-0048-x

9 Abeng FE, Anadebe VC, Idim VD, Edim MM (2020) S Afr J Chem 73:125-130. https://doi.org/10.17159/0379-4350/2020/v73a18

10 Bryksina VA, Tsygankova LE, Kur`yato NA (2014) Theory and Practice of Corrosion Protection [Praktika protivokorrozionnoj zaŝity] 29(3):21-31. (In Russian). https://doi.org/10.31615/j.corros.prot.2024.113.3-2

Жүктеулер

Жарияланды

2025-06-29

Журналдың саны

Бөлім

Environmental Chemistry

Ұқсас мақалалар

Бұл мақала үшін Кеңейтілген нұсқалар бойынша ұқсас мақалаларды іздеу.